Specifications:
 	- Constant output voltage range (CV)
o 0-30VDC continuously variable with fine adjustable for model PS-305 and 0-60VDC continuously variable with fine adjustable for model 8110 and 8112.
 
 	- Load regulation: ≤ 0.01% + 3mV.
 
 	- Line regulation: ≤ 0.01% + 3mV.
 
 	- Recovery time: 100ns typical.
 
 	- Ripple voltage: Peak to peak ≤ 2m Vrms; ≤ 1mV.
 
 	- Temp. coefficient: 5mV / °C typical.
 
 	- Constant current range (CC): (3 Amp for model: PS-303 and 8110; 5 Amp for model: PS-305 and 8112)
 
o Adjustable current Limit:
 	- 5% to 100%, 0.1A to 3A (model: PS-303 and 8110).
 
 	- 5% to 100%, 0.1A to 5A (model: PS-305 and 8112).
 
o Current line regulation: ≤ 0.2% + 3mA, load regulation: ≤ 0.2% + 3mA.
o Ripple current: ≤ 3m Arms.
o Output range: 0 to rating current continuously adjustable.
• Protection: CC / CV indicating lamp
o Protection against reverse polarity, over voltage, short circult, overload
protection fully adjustable, current limiting and fuse primary protection.
• Meter: Built-in type, analog indicator, voltmeter and ammeter each one, ±2.5% of full scale.
| Model | 
Constant Voltage (CV) | 
Constant Current (CC) | 
| PS - 303 | 
0 - 30VDC | 
0 - 3A | 
| PS - 305 | 
0 - 30VDC | 
0 - 5A | 
| 8110 | 
0 - 60VDC | 
0 - 3A | 
| 8112 | 
0 - 60VDC | 
0 - 5A |